Combi-Feedthrough Electrical Current/Thermocouple Type K, mounted on Flange

Electric operation data are given for atmosphere and 10-4 mbar vacuum side.

  • Leak rate: 10-10 mbar l/s
  • Temperature range: -148 to 752 °F (-100 to 400 °C)
  • Maximum temperature gradient: 45 °F/min (25 °C/min)
  • Absolute pressure: 0 - 1000 mbar
  • Including standard miniature plug, temperature range: -85 to 257 °F (-65 to 125 °C)
  • Measurement range: -300 to 2300 °F (-184 to 1260 °C)
  • Thermocouple included is 1 pair of type K: Chromel (+) / Alumel (-)
  • Thermocouple type C, E and J available upon request.
  • Standard material of the two conductors: OFHC Copper. Nickel available upon request.
  • Other flange combinations are available on short notice.
  • Flange material: Stainless steel

Accessories:

Connections
Seals and Gaskets
Screw Sets
Gaskets for CF Flanges
Viton Gaskets

ISO-K

Nominal Width
[NW]
U
[KVolts]
I
[Ampere]
A
[mm]
B
[mm]
C
[mm]
D
[mm]
Item No.Price €Add to
Cart
In Stock
16115881141,3105120XKO016-1-15260,00
16530831142,4102120XKO016-5-30285,00
 

CF

Nominal Width
[NW]
U
[KVolts]
I
[Ampere]
A
[mm]
B
[mm]
C
[mm]
D
[mm]
Item No.Price €Add to
Cart
In Stock
16115881141,3102420XKO016-1-15240,00
16530831142,4102420XKO016-5-30260,00
40115771261,391420XKO040-1-15280,00
40530721262,487420XKO040-5-30310,00
 
 
 

German US Seite Spain France UK